HVAC / GAS FURNACE

CFGH96 Series Gas Furnace

Two-stage heating with an ECM circulator blower. Compare six specification models for your target market and application.

96% AFUEBrochure-listed rating60k-120kBTU/h high-fire input115V / 60HzListed electrical configuration
Compare models
CFGH96 gas furnace angled product view supplied by E Thai

CFGH96 series features

  • Aluminized steel tubular primary heat exchanger and stainless-steel secondary heat exchanger.
  • Two-stage gas valve and hot surface igniter.
  • Multi-speed ECM circulator blower motor.
  • Control board with self-diagnostics and a low-voltage terminal block.
  • Natural gas and propane (LP) convertible configuration, subject to exact-model review.
  • Upflow and horizontal installation configurations described in the product brochure.
  • Left or right gas and electrical service connections; removable bottom for side or bottom return applications.

Installation, fuel conversion, venting and commissioning must follow the approved exact-model instructions and be handled by qualified professionals. This page is product sourcing information, not installation guidance.

CFGH96 gas furnace front view supplied by E Thai

Compare the specification models

The supplied product brochure lists 96% AFUE, 115V / 60Hz, a 104-127V range, an ECM motor rated at 1,050 RPM and five speed modes for all six models. Values below are brochure references, subject to exact-model confirmation.

CFGH96 series - supplied brochure specification comparison
SpecificationCF96U060B3ACF96U080B3ACF96U080C4ACF96U100C5ACF96U100D5ACF96U120D5A
High-fire input (BTU/h)60,00080,00080,000100,000100,000120,000
High-fire output, NG / LP (BTU/h)57,00076,00076,00095,00095,000115,000
Low-fire input (BTU/h)39,00052,00052,00065,00065,00078,000
Low-fire output, NG / LP (BTU/h)37,00049,00049,00062,00062,00075,000
Temperature rise (°F)30-6035-6535-6535-6535-6540-70
Heating static pressure (in. w.c.)0.120.150.150.20.20.2
Minimum circuit ampacity (A)887.811.510.510.5
Maximum overcurrent protection (A)151515202020
Motor horsepower3/43/43/4111
Motor full-load amps (A)Not stated87.811.510.510.5
Blower D x H (in.)12-3/8 x 812-3/8 x 812-6/8 x 11-1/412-6/8 x 11-1/412-6/8 x 11-1/412-6/8 x 11-1/4
Vent diameter listed (in.)2 or 32 or 32 or 32 or 32 or 33
Burner count344556

Dimensions and documentation

Request a dimensioned drawing matched to the exact specification model before installation planning. Cabinet dimensions and shipping weight must be confirmed for the offered variant.

Certification coverage, supporting documents and target-market suitability require model-specific review; certification marks in a brochure do not replace that review.

Prepare a gas furnace RFQ

  • Choose a reference model or state the heating requirement for professional review.
  • Provide the target country, application, fuel and electrical requirements.
  • Identify required documentation, intended order volume and sample evaluation needs.

Specifications, certification evidence, sample availability, MOQ and lead time are confirmed by exact model, target market and RFQ requirements.

Get in Touch With Our OEM Team

Share your target market, expected annual volume, certification needs and customization direction. The team will review the best model path and quotation inputs with you.

Tel
+86 760 89999999

Request a Quote

FAQ

Which HVAC category is currently shown?

Gas Furnace, starting with the CFGH96 series. Other HVAC product types are not implied by this category.